Product Description
Mine Stray Current Tester Manufacturer 

Darui Electric recommends:

Features:



The mine stray current tester manufacturer has a wide measurement range, with a total of twenty ranges, capable of measuring AC/DC stray voltage and stray current separately, without needing a power supply, safe and reliable. It is suitable for testing the current and voltage generated by steel rails, water pipes, cables, etc. in coal mines, preventing electric detonator premature explosions and other combustion and explosion accidents caused by stray current discharge, minimizing fire sources in mines.



Usage methods and precautions:



 1. Before measurement, screw the test rod wires onto the two binding posts respectively, and adjust the meter pointer to the zero scale line.

 2. Place the test rods connected to the binding posts on the two points to be measured (e.g., steel rail, water pipe, cable sheath, coal, ground, etc.). The two test points should be on different conductors, with a distance of about 2 meters. Normally, measure every 50-100 meters, or determine test points temporarily as needed. Set the switch to the appropriate range, and the meter reading, after conversion, gives the corresponding current value.

 3. During measurement, ensure the hard alloy tip of the measuring probe is in good contact with the object being measured, and the instrument should be placed horizontally to ensure accurate readings.

 4. When AC stray current cannot be measured at a location, also test for DC stray current, and vice versa.

 5. When measuring stray voltage values, the ranges are: 50mA corresponds to 0.2V, 250mA to 1V, 1A to 4V, 5A to 20V, 10A to 40V. (i.e., current value multiplied by 4 gives the voltage value)

 6. When the stray current magnitude is unknown, first set to the maximum range, then gradually decrease until the appropriate measuring range.

 7. When the measured current exceeds 5A, the instrument should only be used for short-term measurements; when the measured current exceeds 10A, the instrument should only be used for instantaneous measurements, to avoid burning out components and the meter due to high current.

 8. When measuring DC stray current, if the meter pointer deflects in the reverse direction, swap the test leads.

 9. When the instrument is not in use, set it to the "Off" position.




Note: The above information and technical parameters are compiled and published by Yangzhou Darui Electric Co., Ltd.
WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us