Desktop|中文
Home About Us Products + News Center Technical Articles Messages Contact Us

Product Details

全自动Dielectric Loss Tester-扬州达瑞

Dual-Angle Safe Piercing Device - Yangzhou Dary

Published: 2020-08-12 09:34:08

Views: 2922

Category: Cable Fault Tester

Product Description

Dual-Angle Safe Piercing Device 


Dary Electric recommends:

1. Features




  • The dual-angle safe piercing device is suitable for piercing various power cables, ensuring safe and reliable piercing;

  • The main controller is equipped with dual guns, allowing two different angle piercings in one operation, ensuring operator safety, convenience, and speed;

  • Two working modes: remote control and timed, with dual-key confirmation to enter the working mode, ensuring operator safety;

  • Dual-key remote control (press A and B keys simultaneously), requiring both keys to be pressed at the same time to trigger remotely, preventing accidental single-key presses and improving the accuracy and safety of the remote control;



★ Equipped with real human voice prompts synchronized with LCD display, making operation safer, more accurate, and intuitive under guidance;



★ Multiple mechanical and electronic safety designs, ensuring safety and reliability;




  • Specifically designed for piercing cables, with an attractive appearance, directly fixed onto the cable, safe and convenient, and can be installed at any angle;

  • The power source uses ordinary dry batteries, suitable for field use without external power, while ensuring complete isolation between the piercing device and the power system, guaranteeing power supply safety.



2. Technical Specifications



★ Wireless remote control distance: ≤20 meters



★ Applicable cables: various power cables with diameter ≤¢125mm



★ Weight: complete set including aluminum alloy case: 15kg



★ Dimensions: 45×45×16cm³ (including aluminum alloy case and all accessories)

 



Usage Precautions



1. Operate according to the instructions above.



2. If during piercing, the bolt moves but the nail gun cartridge does not explode, check if item ⑿ is tightened. If loose, tighten and try again. If it still does not explode after tightening, replace the nail gun cartridge. If it still does not explode, contact the manufacturer.



3. If during piercing, the spring inside the gun chamber does not move, but the control box operation is completed, it may be due to long-term storage or poor maintenance. Loosen the bolt force adjustment nut ⑿ a few turns and perform a blank test until the spring moves once, then tighten it and continue testing. If it still does not move, contact the manufacturer.



4. Safety of this device:



<1> Electronic control ensures that even if the device is powered on and the "Confirm" key is accidentally pressed to enter the selected mode, a second confirmation or re-selection of the mode is required; the device will not automatically operate due to accidental entry into timed mode. A second confirmation is required to enter the selected mode.



<2> Electronic control ensures that even if the device is powered on and a key on the remote control is accidentally pressed, the device will not operate. Both keys A and B on the remote control must be pressed simultaneously for the device to operate.



<3> Electronic control ensures that only after the prompt to leave the site is given, and both keys C and D on the remote control are pressed simultaneously, will the device operate.



<4> In timed mode, the remote control is ineffective, preventing accidental remote control presses from causing misoperation.



5. If the display shows "Failure, please check the device and try again", please contact the manufacturer promptly and do not disassemble the control box yourself.



6. If the screen shows low battery, replace the batteries promptly and remove them after each use.



7. Consumables such as nail gun cartridges and nails must be the same specifications and models as those configured at the factory.



8. When installing the piercing device, ensure that the U-shaped groove of the gun head is aligned with the fixing plate to prevent damage to the U-shaped groove from the impact force generated during piercing.



9. During use of the piercing device, after live piercing, always clean the gun chamber with a brush to prevent residual debris from jamming the gun needle and causing malfunction.



10. During use, the device can only pierce cables, not wooden sticks or other items, as the impact force is high and piercing such items may damage the device.



Note: The above information and technical parameters are compiled and released by Yangzhou Dary Electric Co., Ltd.


WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation