1.Before using the lightning counter calibrator, please charge it first. To ensure the charging effect and extend battery life, use the dedicated charger. It takes about 3-4 hours to fully charge an empty battery. The red light on the charger indicates charging; the green light indicates charging is complete.
2、According to the installation height of the counter, properly extend the telescopic discharge rod.
3、For the dedicated grounding wire, insert one end plug into the jack at the rear of the calibrator, and connect the other end clamp to the ground.
4、Press the red button to turn on the high voltage for about 1 second, the indicator light will light up (flicker slightly),
then gently tap the connection end of the counter and the lightning arrester for testing.
5、After each tap, the discharge rod tip should be removed from the counter. If repeated testing is needed, do not release the button. Wait for 1-2 seconds until the indicator light flashes again, then tap again for testing.
6、Continuous testing may cause the calibrator to heat up. Please allow appropriate intervals to reduce malfunctions and extend battery life.
7、The calibrator output has three levels: high, medium, and low, which can be adjusted via the toggle switch on the head to suit testing different types or brands of counters.
8、If the indicator light does not flash after pressing the button for more than 3 seconds, it indicates that the battery needs charging.