Product Description
Lightning Counter Action Tester 

Darui Electric recommends for you:

Features of Lightning Counter Action Tester:



1.  Built-in dedicated Ni-H rechargeable battery pack with large capacity, can test up to 300 times after full charge.



2.  Short test interval (about 1 second), and it does not extend as the battery level drops.



3.  Output has three adjustable levels: high, medium, and low, suitable for verifying the operation of lightning counters of different types and brands.



4.  Rechargeable, completely eliminating the hassle of frequent battery replacement or damage caused by battery leakage.



5.  Small size, light weight, easy to carry.



Technical Parameters:



Output Voltage: 0~1200V adjustable         Capacitance: 10μF



Action Time: 1~2 seconds per time   Power Supply: DC 4.5V * 2 pieces



LCD Display: 9V       Dimensions: 200×115×45mm


 

Lightning Counter Action Tester Usage Method:



1. Please charge before use. To ensure charging effectiveness and extend battery life, use the dedicated charger. It takes about 3-4 hours to fully charge an empty battery. The red light on the charger indicates charging; the green light indicates charging is complete.



2. According to the installation height of the counter, properly extend the telescopic discharge rod.



3. For the dedicated grounding wire, insert one end's plug into the jack at the rear of the calibrator, and connect the other end's clip to the ground.



4. Press the red button to turn on high voltage for about 1 second. The indicator light will illuminate (flicker slightly),



then gently tap the connection point between the counter and the lightning arrester to perform the test.



5. After each tap, the discharge rod tip should be removed from the counter. If repeated testing is needed, do not release the button. Wait for 1-2 seconds until the indicator light flickers again, then tap again for testing.



6. Continuous testing may cause the calibrator to heat up. Please allow appropriate intervals to reduce malfunctions and extend battery life.



7. The calibrator output has three levels: high, medium, and low, adjustable via the toggle switch on the head to suit testing counters of different types or brands.



8. If the indicator light does not flicker after pressing the button for more than 3 seconds, the battery needs to be charged.



9. Do not disassemble the calibrator arbitrarily. If the battery pack capacity drops significantly or charging efficiency is too low, it needs to be replaced. Please purchase the dedicated battery pack from our company.





Note: The above information and technical parameters are compiled and released by Yangzhou Darui Electric Co., Ltd.


WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us