Desktop|中文
Home About Us Products + News Center Technical Articles Messages Contact Us

Product Details

全自动Dielectric Loss Tester-扬州达瑞

Ci Cable Identifier Yangzhou Darui

Published: 2020-08-12 15:47:35

Views: 2922

Category: Mining Stray Current Tester

Product Description

Ci Cable Identifier 

Darui Electric recommends to you:



Working Principle



 In order to reliably and accurately identify cables, the Ci Cable Identifier needs to apply a special signal to the cable to be identified, which can be received by a dedicated receiver. Using this characteristic, the target cable can be identified.



The instrument works on the following principle:



The generator feeds periodic unipolar voltage pulses into the cable to be identified, which needs to be grounded at the far end to ensure sufficient current flows through the cable. The system is designed so that the return current does not flow back through the same cable. To achieve this, the direction of the pulse current fed into the cable can be used as an obvious identification criterion. The outgoing current only passes through this one cable, while all other adjacent cables carry return currents, but with opposite polarity. In addition to the actual difference in current direction, the current amplitude is also an identification feature. The outgoing current passes through only one cable, while the return current may pass through several cables, meaning the outgoing current is larger than the return currents flowing through other cables.

 

The receiver's task is to detect the direction and magnitude of the current flowing through the cable. To achieve this, a current clamp is used as a sensor, which has an amplifier and is connected in series in the circuit. The clamp clamps onto the cable under test. The magnetic field generated by the current flowing through the cable induces a voltage in the clamp's coil. The polarity of this voltage is determined by the current direction and the orientation of the clamp's coil. To obtain a clear voltage polarity indicating the current direction, all cables in a bundle are tested with the same correct winding direction, which is why there is an arrow on the clamp. The direction of the arrow on the clamp should point towards the far end of the cable. The voltage induced in the clamp coil is displayed on the meter. If the clamp is connected as described above, the pointer deflection direction can indicate the current direction. That is, only the cable with outgoing current will cause the pointer to deflect to the right, and this is the cable to be found. All other cables only carry return currents, causing the pointer to deflect to the left, or if there is no pulse current, the pointer does not deflect. The amplifier adjustment on the receiver can adjust the signal strength.



Ci Cable Identifier Function Introduction



Main unit dimensions: 400mm×270mm×210mm 

Receiver dimensions: 155mm×205mm×50mm 



The functions of each part of the main unit are as follows: 

1. Power switch: Controls the on/off of the entire unit's power. 

2. Power input socket: Use the dedicated power cord provided with the instrument to input 50Hz, 220V AC power. When using the instrument, it should be plugged into a three-prong power outlet independently, and the ground wire of the outlet should be directly grounded nearby. 

3. Fuse holder: The instrument uses a 10A fuse. If damaged, replace with a fuse of the same specification. 

4. Black terminal: During testing, insert the matching black test lead (Ф4 plug) into this jack, and connect the other end's test clip to the system ground. 

5. Red terminal: During testing, insert the matching red test lead (Ф4 plug) into this jack, and connect the other end's test clip to the cable core under test. 

6. Meter: Indicates the output current magnitude. 

7. Output adjustment: Used to adjust the main unit's current. During use, adjust appropriately according to the length of the cable under test and the indication on the receiver. Rotate clockwise to increase the output current. 

The functions of each part of the receiver are as follows: 

1. Power switch: Turns the receiver power on and off. 

2. Amplitude adjustment: Rotate clockwise to increase the meter reading on the receiver, rotate counterclockwise to decrease it. 

3. Meter: Indicates the amplitude and polarity of the input signal. 

4. Power indicator light: When the power switch is turned on, the indicator light is on.



Note: The above information and technical parameters are compiled and released by Yangzhou Darui Electric Co., Ltd.


WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy